Millers Falls 68.8KVA Diesel Generator 415V Cummins Powered GSD75CL
Powered by a world-renowned CUMMINS 4BTA3.9-G2 4-cylinder 3.9L turbocharged diesel engine for exceptional durability and performance. Premium Leroy Somer 4-pole brushless alternator with AVR for stable and reliable three-phase power output. Delivers 62.5 kVA prime power with up to 24 hours runtime at 75% load from a 268L double-bunded fuel tank. Low 1500 RPM operation ensures smooth running, reduced engine wear, and long service life. Fuel-efficient consumption at 14.9 litres per hour (75% prime load). Silenced, sound-attenuated canopy operating at just 67 dBA at 7 metres. Oversized 50°C-rated radiator engineered for harsh Australian temperature conditions. Heavy-duty, heat-insulated, lockable cabinet with powder-coated finish for outdoor applications. Fork slippers and lifting hooks for easy transport and positioning. Earth leakage protection with IP67 RCBOs and approved IP66 outlets. RCBO-protected hardwire terminals with additional safety cover. Smartgen 6120 controller for simple monitoring and control. 2-wire remote start capability with ATS connection socket and 4G remote start compatibility. Oil pressure shutdown, over-temperature shutdown, and over-current protection included. Emergency E-stop, shunt relay auto stop, and lockable battery isolator fitted. Interior cabinet light with switch for maintenance convenience. Mine site ready with bunded fuel tank and drain plugs for water, oil, and diesel. Australian compliant wiring with M.E.N link and site-safe lockable canopy. Model: GSD75CL. Prime Power: 50 kW / 62.5 kVA, 415V, 95.6 Amps. Standby Power: 55 kW / 68.8 kVA. Power Factor: 0.8. Phase: Three Phase 415V. Frequency: 50 Hz. Engine: CUMMINS 4BTA3.9-G2, 4 Cylinder 3.9L Turbo Diesel. RPM: 1500/min. Cooling System: Water cooled with 50°C-rated radiator. Alternator: Leroy Somer 4 Pole Brushless Synchronous with AVR. Starting System: 12V electric start with heavy-duty battery and charger. Controller: Smartgen 6120. Remote Start: 2-wire remote start capable. Over Temperature Protection: Yes. Over Current Protection: Yes. Low Oil Protection: Yes. Lockable Battery Isolator: Yes. Emergency Stop: Yes. Shunt Relay Auto Stop: Yes. Noise Level: 67 dBA at 7 metres. Running Time: Up to 24 hours at 75% prime load. Fuel Tank Capacity: 268 Litres with fuel gauge. Fuel Consumption: 14.9 L/hour at 75% prime load. Cabinet: Lockable, fully sound-deadened, powder-coated for external use. Outlets: 1 x 15 Amp IP66 (Single Phase). Outlets: 1 x 20 Amp IP66 (Three Phase). Outlets: 2 x 32 Amp IP66 (Three Phase). Hardwire Terminals: Included, RCBO IP67 protected with extra cover. Dry Weight: 1260 kg. Dimensions: 2300mm (L) x 1100mm (W) x 1580mm (H).
Read full descriptionSpecial Order
Apple Pay, Google Pay, Link and PayPal, no account needed
Delivery to your door
Features
- Powered by a world-renowned CUMMINS 4BTA3.9-G2 4-cylinder 3.9L turbocharged diesel engine for exceptional durability and performance.
- Premium Leroy Somer 4-pole brushless alternator with AVR for stable and reliable three-phase power output.
- Delivers 62.5 kVA prime power with up to 24 hours runtime at 75% load from a 268L double-bunded fuel tank.
- Low 1500 RPM operation ensures smooth running, reduced engine wear, and long service life.
- Fuel-efficient consumption at 14.9 litres per hour (75% prime load).
- Silenced, sound-attenuated canopy operating at just 67 dBA at 7 metres.
- Oversized 50°C-rated radiator engineered for harsh Australian temperature conditions.
- Heavy-duty, heat-insulated, lockable cabinet with powder-coated finish for outdoor applications.
- Fork slippers and lifting hooks for easy transport and positioning.
- Earth leakage protection with IP67 RCBOs and approved IP66 outlets.
- RCBO-protected hardwire terminals with additional safety cover.
- Smartgen 6120 controller for simple monitoring and control.
- 2-wire remote start capability with ATS connection socket and 4G remote start compatibility.
- Oil pressure shutdown, over-temperature shutdown, and over-current protection included.
- Emergency E-stop, shunt relay auto stop, and lockable battery isolator fitted.
- Interior cabinet light with switch for maintenance convenience.
- Mine site ready with bunded fuel tank and drain plugs for water, oil, and diesel.
- Australian compliant wiring with M.E.N link and site-safe lockable canopy.
Specifications
- Model: GSD75CL
- Prime Power: 50 kW / 62.5 kVA, 415V, 95.6 Amps
- Standby Power: 55 kW / 68.8 kVA
- Power Factor: 0.8
- Phase: Three Phase 415V
- Frequency: 50 Hz
- Engine: CUMMINS 4BTA3.9-G2, 4 Cylinder 3.9L Turbo Diesel
- RPM: 1500/min
- Cooling System: Water cooled with 50°C-rated radiator
- Alternator: Leroy Somer 4 Pole Brushless Synchronous with AVR
- Starting System: 12V electric start with heavy-duty battery and charger
- Controller: Smartgen 6120
- Remote Start: 2-wire remote start capable
- Over Temperature Protection: Yes
- Over Current Protection: Yes
- Low Oil Protection: Yes
- Lockable Battery Isolator: Yes
- Emergency Stop: Yes
- Shunt Relay Auto Stop: Yes
- Noise Level: 67 dBA at 7 metres
- Running Time: Up to 24 hours at 75% prime load
- Fuel Tank Capacity: 268 Litres with fuel gauge
- Fuel Consumption: 14.9 L/hour at 75% prime load
- Cabinet: Lockable, fully sound-deadened, powder-coated for external use
- Outlets: 1 x 15 Amp IP66 (Single Phase)
- Outlets: 1 x 20 Amp IP66 (Three Phase)
- Outlets: 2 x 32 Amp IP66 (Three Phase)
- Hardwire Terminals: Included, RCBO IP67 protected with extra cover
- Dry Weight: 1260 kg
- Dimensions: 2300mm (L) x 1100mm (W) x 1580mm (H)
- MPN
- GSD75CL
- Manufacturer
- Millers Falls